Setup of Technology VitalControl:
Categories:
Prior to the first data exchange, the technology coupling to the VitalControl device must be created and set up once.
Attention
Before setting up the technology coupling, check whether the ‘VCSynchronizer’ software is installed on your PC; this software is mandatory for data exchange. To do so, open the Windows Start menu and search the in list of your applications in for an entry named ‘Urban VitalControl’ there. If you can’t find such an entry, install theVCSynchronizer
software on your PC.To set up the technology, proceed as follows:
Create new parameter set for data exchange with VitalControl device
Within the software
Herde
, open theSettings
window. Depending on the configuration of your user interface, you can open this window via the menu itemOrganization
in the main menu (top level item Settings), in the sidebar menu or in your customized toolbox (horizontal or vertical).A pop-up window
Settings
opens, in whose left sidebar numerous setting categories are listed. Open the categoryService
➊ and select the subcategoryTechnology
➋.In the header of the right-hand main area, a dropdown now appears in which all defined technology parameter sets are listed. The number of set up technologies is shown to the right. Click on the button
Create new technology parameter set
➌.Another pop-up window opens. Enter
VitalControl
as Name of the connection andUrban VitalControl (Gen 2)
as Type of Technology and then click theAccept
button..
The parameter set for technology
VitalControl
is now created and must be configured in the next steps.
Configuration: Basic settings
Initially, the tab Basic settings
is selected in the screen displayed, as shown in the figure below. Make adjustments there in the categories External program
➊, Animal data
➋, Locations
➌ and Leaving
➍ according to your farm-specific conditions.
.
Category External program
➊
In order to perform data exchange between VitalControl and Herde Plus, basic software VitalControl Synchronizer is needed as external helper program. For the correct function of this program, some adjustments have to be made in the category External program
➊.
Device name for data exchange:
By default this field is empty. However, it is recommended to enter the name of your computer here. To do so, press the iconArrow down
at the right end of the drop-down field. Your computer name will now be determined and displayed for selection inside the drop down list. Once the field is filled with your computer name and this setting is stored, data exchange can only be triggered from your computer from now on.Execute in path: Please enter
%LOCALAPPDATA%\Urban\VitalControl\Synchronizer
into this input field. This is the absolute path to the programVitalControl Synchronizer
(or more specifically to the filevcsynchronizer.exe
). If the target directory for this program has been changed during the installation of the VCSynchronizer, please enter the selected target directory here.Program HerdePlus 🡒 Technology:
This input field needs to be filled with the valuevc_imp.bat
. The correspondingly named batch file specifies the sequence of operations during data import.Technology 🡒 Program HerdePlus:
This input field needs to be filled with the valuevc_exp.bat
. The correspondingly named batch file specifies the sequence of operations during data export.
Category Animal Data
➋
Further adjustments have to be made in the category ‘Animal data’ ➋ in order to get data exchange fully functional.
- Animal number:
This setting determines which ID animals receive for display on VitalControl device:- If you have assigned short IDs (
Barn no.
, 2 to 6 digits) to your animals, you should select the value ‘Barn number’ here: the displayed ID of an animal on the VitalControl will then correspond to the barn number assigned to the animal. - If you do not have assigned short ID numbers to your animals - this is common in the fattening sector, for example - then you should select the value
Tag no. (5 digits)
here. The displayed ID of an animal on VitalControl device will then correspond to the last 5 digits of the ID printed on the yellow ear tag of the animal.
- If you have assigned short IDs (
- Transmitter no.:
This setting determines the number expected for an animal during RFID scan:- If you put a collar with a transponder on your animals or put an ear transponder on your animals -for example for identification at the automatic feeder-, you should select the value ‘Transponder’ here.
- If your animals or calves carry electronic ear tags encoded with the official national 15-digit identification number of your animal which will serve for the identification of the animal throughout its whole life, you should select the value ‘Tag no. (15 digits)` here.
- Minimum age for transfer:
If0
is entered as value for this input field, all animals will be transferred to the VitalControl device, regardless of their age. A value greater than0
defines the minimum age (in days) for the animals to be transferred. For example, if only cows are to be transferred to the device, a value of 600 days (= 20 months) must be entered here as the minimum age.
Category Locations
➌
Use this category to exclude animals at certain locations from data transfer to the device. To do so, remove the checkmark from the location(s) for which you do not want to transfer the animals housed there to the device.
Category Leaving
➍
Tick the ‘Leaving in HERDEplus’ option here. This way you specify that animals that left the herd are also deleted from VitalControl device during synchronisation.
Also tick the ‘Does not exist in stock’ option. This way you specify that animals on the VitalControl that are not known to Herde
software are deleted from the VitalControl during synchronisation.
Configuration: Technology-specific settings
Next, click on the Technology-specific settings
tab to determine the scope of the data exchange. It is recommended to check all check boxes listed there except for the checkbox Save import file after processing
. The latter checkbox is meant for diagnostic purposes and should be selected only if demanded by service personnel.
Maximum age for transfer:
If0
is entered here as the value, all animals will be transferred to the VitalControl device, regardless of their age. A value greater than0
defines the maximum age (in days) for the animals to be transferred. If, for example, only calves are to be transferred to the device, a value of 90 days (= 3 months) must be entered here as the maximum age..
Save data exchange settings
Press the Save (F2)
key after you have configured all configuration parameters appropriately. The parameter set for data exchange to VitalControl device is now saved and ready for use.
Perform a data exchange now to check whether the stipulated settings are valid so that you successfully can exchange data to and from VitalControl device.