Prior to the first data exchange, the technology coupling to the VitalControl device must be created and set up once.
VCSynchronizer
software on your PC.To set up the technology, proceed as follows:
Within the software Herde
, open the Settings
window. Depending on the configuration of your user interface, you can open this window via the menu item Organization
in the main menu (top level item Settings), in the sidebar menu or in your customized toolbox (horizontal or vertical).
A pop-up window Settings
opens, in whose left sidebar numerous setting categories are listed. Open the category Service
➊ and select the subcategory Technology
➋.
In the header of the right-hand main area, a dropdown now appears in which all defined technology parameter sets are listed. The number of set up technologies is shown to the right. Click on the button
Create new technology parameter set
➌.
Another pop-up window opens. Enter VitalControl
as Name of the connection and Urban VitalControl (Gen 2)
as Type of Technology and then click the Accept
button.
.
The parameter set for technology VitalControl
is now created and must be configured in the next steps.
Initially, the tab Basic settings
is selected in the screen displayed, as shown in the figure below. Make adjustments there in the categories External program
➊, Animal data
➋, Locations
➌ and Leaving
➍ according to your farm-specific conditions.
.
External program
➊In order to perform data exchange between VitalControl and Herde Plus, basic software VitalControl Synchronizer is needed as external helper program. For the correct function of this program, some adjustments have to be made in the category External program
➊.
Device name for data exchange:
By default this field is empty. However, it is recommended to enter the name of your computer here. To do so, press the icon
Arrow down
at the right end of the drop-down field. Your computer name will now be determined and displayed for selection inside the drop down list. Once the field is filled with your computer name and this setting is stored, data exchange can only be triggered from your computer from now on.
Execute in path:
Please enter %LOCALAPPDATA%\Urban\VitalControl\Synchronizer
into this input field. This is the absolute path to the program VitalControl Synchronizer
(or more specifically to the file vcsynchronizer.exe
). If the target directory for this program has been changed during the installation of the VCSynchronizer, please enter the selected target directory here.
Program HerdePlus 🡒 Technology:
This input field needs to be filled with the value vc_imp.bat
. The correspondingly named batch file specifies the sequence of operations during data import.
Technology 🡒 Program HerdePlus:
This input field needs to be filled with the value vc_exp.bat
. The correspondingly named batch file specifies the sequence of operations during data export.
Animal Data
➋Further adjustments have to be made in the category ‘Animal data’ ➋ in order to get data exchange fully functional.
Barn no.
, 2 to 6 digits) to your animals, you should select the value ‘Barn number’ here: the displayed ID of an animal on the VitalControl will then correspond to the barn number assigned to the animal.Tag no. (5 digits)
here. The displayed ID of an animal on VitalControl device will then correspond to the last 5 digits of the ID printed on the yellow ear tag of the animal.0
is entered as value for this input field, all animals will be transferred to the VitalControl device, regardless of their age. A value greater than 0
defines the minimum age (in days) for the animals to be transferred. For example, if only cows are to be transferred to the device, a value of 600 days (= 20 months) must be entered here as the minimum age.Locations
➌Use this category to exclude animals at certain locations from data transfer to the device. To do so, remove the checkmark from the location(s) for which you do not want to transfer the animals housed there to the device.
Leaving
➍Tick the ‘Leaving in HERDEplus’ option here. This way you specify that animals that left the herd are also deleted from VitalControl device during synchronisation.
Also tick the ‘Does not exist in stock’ option. This way you specify that animals on the VitalControl that are not known to Herde
software are deleted from the VitalControl during synchronisation.
Next, click on the Technology-specific settings
tab to determine the scope of the data exchange. It is recommended to check all check boxes listed there except for the checkbox Save import file after processing
. The latter checkbox is meant for diagnostic purposes and should be selected only if demanded by service personnel.
Maximum age for transfer:
If 0
is entered here as the value, all animals will be transferred to the VitalControl device, regardless of their age. A value greater than 0
defines the maximum age (in days) for the animals to be transferred. If, for example, only calves are to be transferred to the device, a value of 90 days (= 3 months) must be entered here as the maximum age.
.
Press the Save (F2)
key after you have configured all configuration parameters appropriately. The parameter set for data exchange to VitalControl device is now saved and ready for use.
Perform a data exchange now to check whether the stipulated settings are valid so that you successfully can exchange data to and from VitalControl device.